AWS A5.28 ER90S-G Solid wire
TEMO WH60-G, GB/T 39281 G59A4HM21Z
Description:
ER90S-G is a gas shielded solid wire used for high-strength steel with a tensile strength of 600MPa. It adopts rich argon gas protection and has excellent comprehensive mechanical properties.
Diameters: Packaging:
0.6mm-4.0mm 1kg, 5kg, 15kg, 250kg,300kg, 350kg
Applications:
Mainly used for welding high-strength steel for important structures of corresponding strength grades. Widely used in fields such as ships, pipelines, engineering machinery, petrochemicals, pressure vessels, bridges, lifting and transportation, high-rise buildings, etc.
Chemical Composition of Deposited Metal (wt.%):
C | Mn | Si | S | P | |
AWS | As agreed between supplier and purchaser. | ||||
GB/T | As agreed between supplier and purchaser. | ||||
Example value | 0.075 | 1.75 | 0.60 | 0.008 | 0.001 |
Mechanical Properties of Deposited Metal:
Tensile strength /MPa | Yield strength /MPa | Elongation /% | Impact J/℃ | |
AWS | ≥620 | As agreed between supplier and purchaser | ||
GB/T | 590-790 | ≥490 | ≥16 | ≥47/-40 |
Example value | 668 | 548 | 25 | 135 |
Weld X - ray Flaw Detection: GradeⅠ
Recommended welding parameters(DC﹢):
Diameter /mm | φ0.8 | φ1.0 | φ1.2 | φ1.6 | |
Current /A | Flat/horizontal welding | 50-180 | 80-250 | 100-360 | 250-500 |
Notes:
1. Using mixed gas protection, gas code M21 (Ar+(15-25%) CO₂).
2. The dry extension length of the welding wire should be controlled within the range of 15-20mm.
3. Before welding, impurities such as rust, oil stains, and moisture must be removed from the welded parts.
4. After unpacking the wire, attention should be paid to taking moisture-proof measures and using it up as soon as possible.
When welding on site, if the wind is too strong, windproof measures should be taken.